Fire protection cavity wall box

Quickbox® Maxi HWD 90 3x1

Quickbox® Maxi HWD 90 3x1
Preview: Quickbox® Maxi HWD 90 3x1
Quickbox® Maxi HWD 90 3x1
  • 9499-77.03
  • 372632809
  • 7611614276809
  • compatible with Feller SNAPFIX®
  • for F30-F90 or EI30-EI90 fire-protection walls
  • VKF Approval 26831
  • also for opposing installation
  • for plate thickness >10 - 40 mm
  • matching plug-in cover for Art. No. 9498-77 New Look one Art. No. 9919.10
  • For device screws Ø 3 mm
  • Max. tightening torque 0.5 Nm
  • Pipes must be sealed with sealing plugs on both sides of the pipes!
Length
205 mm
Width
83 mm
Depth
73.5 mm
Cut hole Ø
83 mm
Tube entries up to M25
2
Combination
3x1
Dispatch
5
Product information

Fire protection cavity wall box

HWD 90 cavity wall boxes for EI30-EI90 fire-protection walls ensure certified and fire-protection compliant electrical installation. Intelligent AFS technology reacts immediately to fire and heat and automatically seals the installation opening. This guarantees the fire resistance class of the fire-protection wall and secures escape routes. Use in all fire-protection walls and the fire-resistance duration of up to 90 minutes ensures maximum flexibility, even when the planning is changed. At the same time, it also maintains the wall's sound insulation requirements.

  • compatible with Feller SNAPFIX®
  • For fire-protection walls F30-F90 or EI30-EI90
  • Maintains the wall's sound insulation protection
  • Retrofitting also possible
  • With fire-protection cover, can be used as a junction box
  • Also for directly opposing installation
  • May not be used inside encapsulated walls
  • does not match with the following types:
  • Prestige model by Feller Edizio Due

Processing note

Final assembly of certain flush-mounted devices for unplastered surfaces: Due to the contact edge of the box, a small joint may form between the cover and the wall surface. If the surface is not plastered, it is advisable to countersink the edge of the box holder into the wall to avoid any joints.

Montage Quickbox Maxi HWD 90 in Brandschutzwänden EI30 - EI90

Installationsöffnung Ø 83 mm mit einem Fräser (z. B. Bi-Metall-Fräser 1082-84) erstellen.

Bore precise entry holes for the tubes

Tubes must be sealed with sealing plugs.

Dose mit den zwei vormontierten FX4-Schrauben befestigen.

Montage Quickbox Maxi HWD 90 in Brandschutzwänden EI30 - EI90

Installationsöffnung Ø 83 mm mit einem Fräser (z. B. Bi-Metall-Fräser 1082-84) erstellen.

Bore precise entry holes for the tubes

Tubes must be sealed with sealing plugs.

Dose mit den zwei vormontierten FX4-Schrauben befestigen.

Certificates
Certificate

VKF approval Quickbox Maxi HWD 90

Select download
Certificate

9499-77.03 Fire-stop box Quickbox Maxi HWD90, 3x1, depth 73.5 mm

Certificate

Test report in short form 9499-77.XX Maxi HWD90

Certificate

Sound-insulation certificate 9499-77 Quickbox Maxi HWD 90

4.1 MB

Download
Product data sheet

Quickbox® Maxi HWD 90 3x1

Article no: 9499-77.03

Download
Instruction

Assembly instructions fire protection and sound insulation boxes.

Instructions available in German and French.

Select download
Instruction

Fire-stop box Quickbox HWD90 Maxi.

Deep fire-stop box Quickbox HWD90 for electrical installations in fire-protection walls EI 30 - EI 90.

For installations with tubes.

582.8 KB | 2018-10-04